Tekbox TBTC0 TEMZelle mini

€547,10

TEM cell "mini" for simple and cost-effective measurement of interference radiation and interference immunity A TEM cell (Transverse E lectro M agnetic Cell) is used to record test objects for measuring and testing the interference radiation and interference immunity of electronic devices. The inter

Availability: In stock
-
+
Secure payment · Fast delivery
EAN:139907Categories:COMPUTER SCIENCE, Peripherals & Accessories, Miscellaneous AccessoriesBrand:

["TEM cell \"mini\" for simple and cost-effective measurement of interference radiation and interference immunity A TEM cell (Transverse E lectro M agnetic Cell) is used to record test objects for measuring and testing the interference radiation and interference immunity of electronic devices. The interference radiation is usually measured in reflection-free rooms and the interference signals are picked up using antennas. Due to bandwidth limitations, different antennas are required to cover the entire frequency range. Furthermore, you need a lot of space and the costs of the equipment for a standard-compliant structure are enormous. What is required is an affordable laboratory setup to measure the interference radiation in your own laboratory before acceptance in the EMC test house. The TEM cells from Tekbox now come in four different sizes and cover a very large frequency range. The new mini TEM cell TBTC0 can be used for frequencies up to 6 GHz. In conjunction with a spectrum analyzer, products can be tested before and after EMC-relevant modifications. The test setup with a TEM cell provides valuable information as to whether the design has major defects with regard to radiated interference signals. The engineer can clearly see whether his changes have worsened or improved the EMC behavior. The TBTC0 is a so-called “open TEM cell” because it has no side walls to make it easier to place the DUT (Device Under Test). Interfering radiation from outside can penetrate the cell, but can be easily identified by measuring the cell's output signal with the DUT switched off and can therefore be taken into account in the measurement result. A TEM cell consists of a septum, the conductive plane in the middle and outer walls connected to ground. The geometry is dimensioned such that an impedance of 50 Ω results. The DUT is placed between the lower wall (floor) and septum. Tekbox's TBTC0 offers better frequency response than standard TEM cells of the same size. TEM cells suffer from undesirable vibration modes at higher frequencies, which limit the usable bandwidth. An outstanding design feature of the Tekbox TEM cells is the implementation of a resistance normal to the direction of wave propagation. Higher order modes and resonances are effectively suppressed. The TEM cell is supplied together with a 50Ω/10W RF terminator and a DC blocker to protect the input of the spectrum analyzer or RF receiver. TEM cell including DC blocker (N-plug/N-socket), 10W HF terminating resistor (N-plug), 1 m coaxial cable (N-plug/N-plug). * Each TEM cell comes with a measurement report (plot) for return loss S 11 and insertion loss S 21", "Dimensions (L x W x H): 390 x 100 x 62 mm", "Rectangular area under the septum: 190 x 70 mm", "Septum height: 28 mm", "Maximum volume of the test specimen (L x W x H): 114 mm x 42 mm x 15 mm", "TEM cell connections: N sockets", "Nominal cell impedance: 50 Ω", "Characteristic impedance: 377 Ω", "Maximum RF input power: 10W (limited by 50Ω termination resistor, 50Ω-6GHz-10W-N)", "Return loss* S 11: up to 3.15 GHz: < -15 dB", "Insertion loss* S 21: up to 3 GHz: < 3 dB, up to 6 GHz: < 4 dB", "Connections: N plug/socket", "Nominal impedance: 50Ω", "Max. HF continuous power: 2 W", "Max. HF continuous voltage: 50 V RMS", "Frequency: 500kHz to 6GHz", "Standing wave ratio: ≤1.2", "Connection: N plug", "Nominal impedance: 50Ω", "Max. HF continuous power: 10 W", "Frequency: DC to 6GHz", "Standing wave ratio: ≤1.2", "3rd order intermodulation product: ≤120 dBc"]

Specifications

Specifications
Frequenz [MHz]0,3
Insertion loss [dB]7,5
Dimensions (L x W x H)390 x 100 x 62 mm
Rectangular area under the septum190 x 70 mm
Septum height28 mm
Maximum volume of the test specimen (L x W x H)114 mm x 42 mm x 15 mm
TEM cell connectionsN-Buchsen
Nominelle Zellenimpedanz50 Ω
Wellenwiderstand377 Ω
Maximum RF input power10 W (begrenzt durch 50 Ω Abschlusswiderstand, 50Ω-6GHz-10W-N)
Return loss* S 11bis zu 3,15 GHz: &lt; -15 dB
Insertion loss* S 21bis zu 3 GHz: &lt; 3 dB, bis zu 6 GHz: &lt; 4 dB
ConnectionsN-Stecker/Buchse
Nominelle Impedanz50 Ω
Max. HF continuous power2 W
Max. HF continuous voltage50 V RMS
Frequenz500 kHz bis 6 GHz
standing wave ratio≤1,2
AnschlussN-Stecker
3rd order intermodulation product≤120 dBc
0.00
0 reviews
0 reviews for "Tekbox TBTC0 TEMZelle mini"

Add a review

Your email address will not be published. Required fields are marked *

Overall ratings
Follow Us

We make consolidating, marketing and tracking your social media website easy.

Sign Up To Newsletter

Join 60.000+ subscribers and get a new discount coupon on every Saturday.