Tekbox TBLC08 50 µH ZweileiterNetznachbildung VLISN bis 240V8A
The 50µH LISN TBLC08 is a two-wire V-network simulation for measuring unbalanced interference voltages on the mains supply line of devices with a single-phase AC power supply. The interference voltage between the two conductors (phase or neutral conductor) and the earth reference point is measured s
Availability: In stock
["The 50µH LISN TBLC08 is a two-wire V-network simulation for measuring unbalanced interference voltages on the mains supply line of devices with a single-phase AC power supply. The interference voltage between the two conductors (phase or neutral conductor) and the earth reference point is measured separately using a changeover switch. The frequency range for EMC precompliance testing according to CISPR 16/EN55011 is 9 kHz to 30 MHz. The TBLC08 network simulation is looped into the supply line of the DUT (Device Under Test). Conducted interference that occurs on the DUT's supply can be measured via the BNC connection in conjunction with a spectrum analyzer or measurement receiver. The network simulation has a switchable attenuator with limiter and 150 kHz high-pass filter. The network simulation is designed for a maximum of 240 V/8 A. The network simulation is constructed with air coils to avoid measurement errors caused by saturation effects", "Frequency range: 9 kHz…30 MHz", "Replicated impedance: 50 Ω || (50 µH+5 Ω)", "Artificial Hand / Artificial Hand: 220 pF + 511 Ω", "Protective conductor can be switched from the DUT: either direct connection to the protective conductor of the LISN or via 50 Ω || 50µH", "Attenuator/limiter/filter (switchable): Attenuation: 10 dB, Schottky diode and high-pass filter: 150 kHz…30 MHz", "Mains voltage: 240 V; 50-60 Hz, CAT II", "DUT connection as standard via Schuko socket (CE7/3), country-specific on request", "Max. operating current: 8 A @ 23°C; Fuse: 2 x 8 A slow (L, N)", "RF output: 50Ω BNC socket", "Measuring path switchable: 0 (neutral conductor), OFF, 1 (phase)", "Operating temperature: +5°C..+40°C", "Humidity relative: 5%..80%", "Calibration data according to CISPR 16-1-2 Appendix 8 attached", "Protection class 1: EN61010-1/IEC1010-1"]
Specifications
| Frequenzbereich | 9 kHz…30 MHz |
| Nachgebildete Impedanz | 50 Ω || (50 µH+5 Ω) |
| Artificial hand / Artificial hand | 220 pF + 511 Ω |
| Schutzleiter vom DUT schaltbar | either direct connection to the protective conductor of the LISN or via 50 Ω || 50µH |
| Attenuator/limiter/filter (switchable) | Attenuation: 10 dB, Schottky diode and high pass filter: 150 kHz…30 MHz |
| Mains voltage | 240 V; 50-60 Hz, CAT II |
| Max. Betriebsstrom | 8A @ 23°C; Fuse: 2 x 8 A slow (L, N) |
| HF-Ausgang | 50 Ω BNC-Buchse |
| Messpfad schaltbar | 0 (Nullleiter), OFF, 1 (Phase) |
| Betriebstemperatur | +5°C..+40°C |
| Humidity relative | 5%..80% |
| Schutzklasse 1 | EN61010-1/IEC1010-1 |