ALLNET / ALL-LAN-ISO-4kV, LAN Gigabit-Isolator/PoE Blocker 4kV ALL-LAN-ISO-4kV
Plug & Play - no installation required Suitable for all systems with a network connection APPLICATIONS: DEVICE PROTECTION Protection of particularly valuable devices from hum and overvoltage from the network peripherals. MEASUREMENT TECHNOLOGY Protection of electrical measuring and monitoring device
Availability: In stock
["Plug & Play - no installation required Suitable for all systems with a network connection APPLICATIONS: DEVICE PROTECTION Protection of particularly valuable devices from hum and overvoltage from the network peripherals. MEASUREMENT TECHNOLOGY Protection of electrical measuring and monitoring devices from external and interference voltages from Ethernet cabling. POTENTIAL DIFFERENCES (BUILDING ENGINEERING) Prevention of potential equalization currents in computer systems that are galvanically connected to one another over large distances via Ethernet cabling. AUDIO Reduction of low-frequency alternating voltages (mains hum) caused by the network connection to an imperceptible level. Suitable for all systems with a network connection", "Gigabit Ethernet (10/100/1000MBit/s)", "IEEE 802.3ab compliant", "4kVrms withstand voltage", "Galvanic isolation: creepage distance: 12.8mm, clearance distance: 12.2mm", "no restrictions on cable length", "ESD protection: Suppression of transient overvoltages on the signal lines", "suitable for devices with a supply voltage of up to 250 Vrms", "not suitable for use with PoE devices", "Dimensions 80x58x24mm"]
Specifications
| Dielectric strength signal and shielding | 5000 V 50/60 Hz for 1 min; 10,000 V DC over 10 s |
| Datendurchsatz | 10/100/1000 MBit/s |
| Connections | 2x RJ45 Ein-/Ausgang |
| Network specifications | IEEE 803.2 from 10/100/1000-BaseT, twisted pair, auto-conf. (behaves completely transparently in the network) |
| Material | UL94V-0/RoHS-konform/SvHC/REACH |
| Product Rating (UL) | Passive electronic components, insulation level DI (250 V AC / 300 V DC) tested at 4 kV AC |
| Betriebsart | Dauerbetrieb |
| Operating time between failures | 0,21x 10 8 (1 Fehler in 21.000.000 h) |
| ESD | 16 kV |
| DC Stress-Test (10 s) | 10 kV |
| Return Loss | min. 10 dB |
| Insertion Loss | max. 1,3 dB |
| Abmessungen (mm, LxBxH) | 80 x 58 x 24, ca. 39 g |
| Standards | IEC 60601-1 1x MOPP up to 250Vrms (the built-in network transformer) |
| Vicinity | Operation and storage: -40...+70°C 10...75% rel. Humidity non-condensing |
| Galvanic isolation | Kriechstrecke: 12,8mm, Luftstrecke: 12,2mm |
| ESD-Schutz | Suppression of transient overvoltages on the signal lines |